Short answer An AQL table tells the inspector how many units to open and how many defects to accept. Find the code letter from lot size and inspection level (II by default), read the sample size, then the accept/reject numbers. Example: 2,400 units at level II means 125 units; at AQL 2.5, 7 major defects pass and 8 fail.
Key takeaways
Three lookups, in order: lot size and level give a code letter; the letter gives a sample size; the AQL column gives Ac/Re.
The standard changed in January 2026. ISO 2859-1:2026 (third edition) replaced the 1999 edition; China's GB/T 2828.1-2012 still copies the 1999 text.
Level II is the default: 125 units for a lot of 1,201 to 3,200, and 200 units for 3,201 to 10,000.
Common convention is 0/2.5/4.0: no critical defects, AQL 2.5 for major and 4.0 for minor, per V-Trust, QIMA and InTouch.
Each class is judged on its own. One class at its reject number fails the lot, even when the others pass.
Some links on this page are affiliate links. We may earn a commission at no extra cost to you. It never changes our ranking. How we make money
Your inspection report says "AQL 2.5, level II, 125 pcs, 6 major, accepted". To check that line, you need the AQL table. Most guides show a blurry image of it, which does not let you check the inspector.
This guide gives you the full tables in text for the six AQL values importers use. It adds the 2026 edition, the arrows, special levels, switching rules, three worked examples and a clause for your purchase order.
How to read an AQL table in three lookups
AQL stands for acceptance quality limit. It is the worst process average you are willing to accept, expressed as defective units per hundred. The tables come from ISO 2859-1, "Sampling procedures for inspection by attributes".
You need four inputs: the lot size, the inspection level, the plan type and the AQL for each defect class. With those four, every inspector should reach the same sample and limits.
Here is what this means in practice. A buyer orders 2,400 units and asks for general level II. Table 1 gives code letter K. Table 2-A gives a sample of 125 units for K. In the AQL 2.5 column, K reads 7/8.
The first number is Ac, the acceptance number: up to 7 major defects, the lot passes for that class. The second is Re, the rejection number: 8 or more, it fails.
This page focuses on single sampling under normal inspection, which covers almost all third-party inspections in China. For what the inspector does on the day, see our pre-shipment inspection guide.
Which standard: ISO 2859-1:2026, GB/T 2828.1-2012 and ANSI/ASQ Z1.4
Three related names appear on inspection reports. ISO 2859-1 is the international standard. ANSI/ASQ Z1.4-2003 (R2018) is its US twin, and QIMA states its own published tables are based on the Z1.4 family. GB/T 2828.1-2012 is the Chinese national standard that factories quote.
ISO published the third edition, ISO 2859-1:2026, in January 2026. Its foreword says it cancels and replaces the 1999 edition. It also absorbs the 2001 correction and the 2011 amendment.
What changed in 2026? The foreword adds a switch to skip-lot inspection, with rules on qualifying producers and choosing lots at random. The printed OC curves were removed; Annex E explains how to build them.
The foreword does not list a change to the code letters or to the accept/reject numbers. Quality Magazine reported that the plan tables were "modified to enhance usability". The values in this guide come from published 1999-based tables. Treat their match with the 2026 text as indicative until you check your own licensed copy.
GB/T 2828.1-2012 was released on 05/11/2012 and took effect on 15/02/2013. Its foreword marks it as identical (IDT) to ISO 2859-1:1999. So a factory quoting GB/T and a buyer quoting ISO normally read the same numbers.
📌 Note: The 2026 edition is a paid document. Name the edition in your contract either way.
Lot size to code letter to sample size: the AQL chart, Table 1
The first table turns your lot size into a sample size code letter. Pick the row that contains your lot size, then the column for your inspection level. The general levels are I, II and III. The special levels are S-1 to S-4.
| Lot size (units) | S-1 | S-2 | S-3 | S-4 | I | II | III |
|---|---|---|---|---|---|---|---|
| 2 to 8 | A | A | A | A | A | A | B |
| 9 to 15 | A | A | A | A | A | B | C |
| 16 to 25 | A | A | B | B | B | C | D |
| 26 to 50 | A | B | B | C | C | D | E |
| 51 to 90 | B | B | C | C | C | E | F |
| 91 to 150 | B | B | C | D | D | F | G |
| 151 to 280 | B | C | D | E | E | G | H |
| 281 to 500 | B | C | D | E | F | H | J |
| 501 to 1,200 | C | C | E | F | G | J | K |
| 1,201 to 3,200 | C | D | E | G | H | K | L |
| 3,201 to 10,000 | C | D | F | G | J | L | M |
| 10,001 to 35,000 | C | D | F | H | K | M | N |
| 35,001 to 150,000 | D | E | G | J | L | N | P |
| 150,001 to 500,000 | D | E | G | J | M | P | Q |
| 500,001 and over | D | E | H | K | N | Q | R |
Each code letter maps to one sample size: A 2, B 3, C 5, D 8, E 13, F 20, G 32, H 50. Then J 80, K 125, L 200, M 315, N 500, P 800, Q 1,250 and R 2,000. The letters I and O are skipped.
Level II is the default unless the contract says otherwise, and V-Trust names it so. Level I opens about 0.40 times the level II sample; it suits repeat orders from a clean factory. Level III opens about 1.60 times as many units. Use it for first orders, high-value goods or after a failed lot.
Fees and rules change often. Get the TRG Importer Brief: one short email a week with changes that affect importers.
Accept/reject numbers: single sampling, normal inspection (Table 2-A)
This is the core of the AQL table. Find your code letter row, then the column for your AQL. The cell gives Ac / Re. Values were cross-checked against IS 2500 (Part 1), an official text identical to ISO 2859-1:1999, and published inspection-company charts.
| Code letter | Sample size | AQL 0.65 | AQL 1.0 | AQL 1.5 | AQL 2.5 | AQL 4.0 | AQL 6.5 |
|---|---|---|---|---|---|---|---|
| A | 2 | ↓ | ↓ | ↓ | ↓ | ↓ | 0/1 |
| B | 3 | ↓ | ↓ | ↓ | ↓ | 0/1 | ↑ |
| C | 5 | ↓ | ↓ | ↓ | 0/1 | ↑ | ↓ |
| D | 8 | ↓ | ↓ | 0/1 | ↑ | ↓ | 1/2 |
| E | 13 | ↓ | 0/1 | ↑ | ↓ | 1/2 | 2/3 |
| F | 20 | 0/1 | ↑ | ↓ | 1/2 | 2/3 | 3/4 |
| G | 32 | ↑ | ↓ | 1/2 | 2/3 | 3/4 | 5/6 |
| H | 50 | ↓ | 1/2 | 2/3 | 3/4 | 5/6 | 7/8 |
| J | 80 | 1/2 | 2/3 | 3/4 | 5/6 | 7/8 | 10/11 |
| K | 125 | 2/3 | 3/4 | 5/6 | 7/8 | 10/11 | 14/15 |
| L | 200 | 3/4 | 5/6 | 7/8 | 10/11 | 14/15 | 21/22 |
| M | 315 | 5/6 | 7/8 | 10/11 | 14/15 | 21/22 | ↑ |
| N | 500 | 7/8 | 10/11 | 14/15 | 21/22 | ↑ | ↑ |
| P | 800 | 10/11 | 14/15 | 21/22 | ↑ | ↑ | ↑ |
| Q | 1,250 | 14/15 | 21/22 | ↑ | ↑ | ↑ | ↑ |
| R | 2,000 | 21/22 | ↑ | ↑ | ↑ | ↑ | ↑ |
Read it like this: at code letter M (315 units) and AQL 4.0, accept up to 21 defects and reject at 22. At AQL 0.65 the same row reads 5/6.
1. Follow the arrows
Some cells hold an arrow instead of numbers. A down arrow (↓) means "use the first plan below, with its sample size". An up arrow (↑) means "use the first plan above, with its sample size".
Global Sources gives a clear case. An order of 300 tablets at level II gives letter H, 50 units. But at AQL 0.65, the H cell is a down arrow. You move to J and open 80 units, with Ac 1 / Re 2. If a sample size equals or exceeds the lot, inspect every unit.
Up arrows work the other way. A lot of 500 units at level I gives letter F, 20 units. At AQL 1.0, F is an up arrow, so you use E: 13 units, Ac 0/Re 1.
2. The AQL is not the defect rate you will see
A common mistake is to read AQL 2.5 as "2.50% defects allowed in the sample". At 200 units, AQL 2.5 accepts 10 defects. That is 5.00% of the sample, double the AQL value.
The reason is statistics. The AQL is a process average that the plan accepts most of the time. The plan must not reject a good factory because one sample was unlucky. So the accept number sits above the AQL share, especially on small samples. If that would hurt you, choose a lower AQL.
Critical, major and minor defects: which AQL for each class
Choosing the AQL is a business decision. Global Sources lists four factors: what the supplier agreed to meet, your inspection budget, your exit-factory date and the value of the goods. Lower AQLs often mean larger samples, so they cost more inspection time.
ISO 2859-1 lets you set a different AQL for each class of nonconformity. It does not impose values. The values below are industry conventions published by inspection companies, not rules of the standard.
| Class | What it means | Common convention | Stricter option |
|---|---|---|---|
| Critical | Could harm a user or break the law | Not allowed (Ac 0 / Re 1, often written "AQL 0") | Check every unit for that defect |
| Major | Product fails or is likely returned | AQL 2.5 | AQL 1.0 or 1.5 for high-value goods |
| Minor | Cosmetic, product still usable | AQL 4.0 | AQL 2.5 or 4.0 for high-value goods |
V-Trust publishes exactly this split. It suggests major AQL 1.0 or 1.5 and minor AQL 2.5 or 4.0 for high-value products. QIMA writes that AQL 2.5 is the most common level for general consumer goods. It adds that AQL 1.0 is used for higher-risk categories. The InTouch article on Global Sources recommends 0, 2.5 and 4.0 for consumer goods.
"AQL 0" does not exist as a column in ISO tables. In practice it means one critical defect fails the lot, whatever the sample size. ISO 2859-1 also has a "special reservation for critical classes" clause.
The class of each defect must be written down before the inspection. Put the list in your spec; our product specification sheet guide shows where it belongs.
Special inspection levels S-1 to S-4 for tests and measurements
Some checks are slow, costly or destroy the unit, such as a carton drop or seam pull test. For these, the standard offers special levels S-1 to S-4, with much smaller samples.
Use the same Table 1, just a different column. For a lot of 3,201 to 10,000 units, S-3 gives letter F, so 20 units, against 200 units at level II. Then read Table 2-A as usual. At AQL 2.5, letter F gives Ac 1 / Re 2.
1. When to use S-1 or S-2
Use them for destructive or very costly tests where results rarely vary between units. S-2 gives 8 units for most medium lots.
2. When to use S-3 or S-4
Use them for functional tests and measurements that take time but tell you more. S-4 gives 32 units for a lot of 3,201 to 10,000.
Small samples miss more, so keep special levels for tests, not for the main visual check.
Switching rules: normal, tightened, reduced and skip-lot inspection
The tables above are for normal inspection, where every new supplier starts. The switching rules move a continuing series of lots to stricter or lighter plans, based on the producer's record.
1. Normal to tightened
Switch to tightened when 2 lots out of 5 or fewer consecutive lots are not accepted. Tightened inspection keeps the sample size but lowers the accept numbers. Return to normal after 5 consecutive lots are accepted on tightened inspection.
2. Discontinuation
If 5 lots in total are not accepted while on tightened inspection, the standard says stop. You resume, on tightened, only after the supplier has fixed the cause. For an importer, this is the signal to audit the factory or change supplier.
3. Normal to reduced
Reduced inspection uses smaller samples. It needs a switching score of at least 30, steady production and approval by the responsible authority, which means you. With Ac 2 or more, add 3 if the lot would pass at the next tighter AQL. With Ac 0 or 1, add 2 per accepted lot. Otherwise the score resets to zero. Return to normal as soon as one lot is not accepted or production becomes irregular.
4. Skip-lot, new in 2026
The 2026 edition adds a switch from normal or reduced to skip-lot inspection. A qualified producer then has only some lots inspected, chosen at random.
Most importers place few orders per product, so the rules rarely apply in full. Still, after a failed lot, asking for tightened inspection next time follows the standard.
Worked examples: three orders, three AQL plans
All three are examples with fictional companies, using only the tables above.
Example 1: 2,400 phone cases for a Riyadh retailer
A Riyadh importer orders 2,400 phone cases. The contract says single sampling, normal inspection, level II, AQL 0/2.5/4.0.
| Line | Lookup or count | Result |
|---|---|---|
| 1. Lot size | 2,400 falls in 1,201 to 3,200 | Row 10 of Table 1 |
| 2. Code letter | Level II column | K |
| 3. Sample size | K in Table 2-A | 125 units |
| 4. Critical | Not allowed; 0 found | 0 < Re 1: pass |
| 5. Major | K at AQL 2.5 = 7/8; 6 found | 6 ≤ Ac 7: pass |
| 6. Minor | K at AQL 4.0 = 10/11; 11 found | 11 ≥ Re 11: fail |
| 7. Minor share | 11 ÷ 125 | 8.80% of the sample |
| 8. Lot verdict | One class failed | Rejected |
The buyer now holds the balance and asks for rework. The factory sorts the lot and fixes the minor faults. Then the re-inspection uses the same plan or a tighter one, never a smaller sample. If the factory disputes the count, see our guide to claims for defective goods from a China supplier.
Example 2: 300 power banks for a Rotterdam distributor
A Dutch buyer orders 300 power banks. Batteries justify tighter limits: level II, critical not allowed, major AQL 0.65, minor AQL 1.5.
The lot of 300 gives letter H, 50 units. At AQL 0.65, H is a down arrow, so major defects are judged on J: 80 units, Ac 1 / Re 2. At AQL 1.5, H reads 2/3 on 50 units. The inspector therefore draws 80 units.
The clause should say how to judge minor defects: the first 50 units at 2/3, or all 80 at J, AQL 1.5, which reads 3/4. The inspector finds 1 major and 3 minor. Under the J option, both pass. Under the 50-unit option, the lot fails if all 3 minor defects are in the first 50.
Example 3: 12,000 T-shirts for a Houston importer
A Houston company orders 12,000 cotton T-shirts at level II, AQL 0/2.5/4.0. It adds a seam strength test at S-3, AQL 2.5. The lot falls in 10,001 to 35,000.
The visual check uses letter M, 315 units: major 14/15 and minor 21/22. The seam test uses S-3, letter F, 20 units, with Ac 1 / Re 2. Results: 0 critical, 12 major, 18 minor and 1 failed seam. Every class stays at or under Ac, so the lot is accepted.
How to write the AQL clause in your purchase order
A vague line such as "inspection to AQL 2.5" leaves open the level, the plan, the classes and the remedy. Six short lines close those gaps.
🔎 In detail: Sample clause. "Acceptance inspection per ISO 2859-1:2026 (equivalent tables: GB/T 2828.1-2012), single sampling, normal inspection, general inspection level II. Critical defects: not allowed (Ac 0). Major: AQL 2.5. Minor: AQL 4.0. Tests in Annex C at special level S-3, AQL 2.5. Defect classes per Annex B. Inspector draws all samples at random. If the lot is not accepted, the seller sorts, reworks and pays the re-inspection."
Put the clause in the contract and spec sheet, signed by the factory. Our contract clauses guide for Chinese suppliers shows where it fits. Then book an inspector; the QIMA vs HQTS vs V-Trust comparison covers prices and booking.
Give the Chinese version too. Factories know the GB/T number and terms such as 一般检验水平 II (general inspection level II).
AQL by region: MENA, Europe/UK, USA
An AQL plan is a commercial check between you and the seller. It does not prove legal compliance in your market.
MENA: Saudi imports of regulated goods need certificates on the SABER platform. A passed AQL report does not replace them.
Europe/UK: the EU General Product Safety Regulation (EU) 2023/988 applies from 13/12/2024. Safety defects belong in your critical class.
USA: the CPSC requires a General Certificate of Conformity for many products. Children's products need a CPC based on third-party lab tests.
For the full import process in each region, start with how to import from China, step by step.
What goes wrong with AQL in practice
1. "AQL 2.5" with nothing else
Without a level and a class, the factory may read it as level I or apply it to every defect. Always write level, plan and AQL per class.
2. The factory picks the cartons
A random sample is the whole basis of the method. The inspector should choose cartons from all over the stack, including the bottom rows.
3. Cutting the sample to save time
Some reports show 80 units where the table says 125. Check the sample size and Ac/Re against the tables above on every report.
4. Reading Ac as a defect target
An accepted lot can still contain 5.00% or more defectives, as shown above. If your margin cannot absorb that, lower the AQL or add a 100.00% check of one key feature.
AQL table checklist before the inspection
Related guides
Pre-Shipment Inspection China (2026): Cost from USD 268.00
16 min read
QualityProduct Specification Sheet for China: Template + AQL
17 min read
QualityQIMA vs HQTS vs V-Trust: Inspection Company in China
14 min read
Free toolSetup Route Finder: which company and bank fit you?
7 questions, 2 minutes
Glossary
AQL (acceptance quality limit): the worst tolerable process average, in defective units or defects per 100 units.
Code letter: the letter A to R from Table 1 that fixes the sample size.
Ac / Re: acceptance number and rejection number for one defect class.
General inspection level: I, II or III; sets the sample size for the main visual check.
Special inspection level: S-1 to S-4; small samples for tests and measurements.
FAQ
What is the most common AQL for consumer goods?
AQL 2.5 for major defects and 4.0 for minor, with no critical defects allowed. This is a convention from inspection firms, not a rule of ISO 2859-1.
How many units are inspected for 1,000 pieces?
A lot of 1,000 falls in 501 to 1,200, which is letter J at level II. The inspector opens 80 units, unless an arrow in your AQL column changes it.
What does AQL 2.5 mean in plain words?
The plan accepts lots from a process that averages 2.50 defective units per 100 most of the time. One sample may show more, up to the acceptance number.
Is ISO 2859-1:2026 different from the 1999 tables?
The foreword lists skip-lot rules and removed OC curves as the main changes. It lists no change to the Ac/Re values; confirm in your licensed copy.
Is GB/T 2828.1 the same as ISO 2859-1?
GB/T 2828.1-2012 is marked identical to ISO 2859-1:1999, so it gives the same numbers as the 1999 tables.
Why is my sample larger than the table says for my lot?
Your AQL column probably shows a down arrow for your code letter. You then use the next plan below, with its larger sample size.
When should I use special level S-3?
For tests that take time or destroy units, such as seam pull tests. It gives far smaller samples than level II.
What happens after a lot is rejected?
The supplier sorts and reworks, then the lot is re-inspected with the same plan.
This guide is general information about sampling standards and is not legal, tax or financial advice. Confirm the edition and tables with your inspection company.
Sources
15 official and provider pages, each with the date we checked it
ISO: ISO 2859-1:2026 Sampling procedures for inspection by attributes, Part 1 (checked 22/11/2026)
ANSI Webstore: preview of ISO 2859-1:2026, foreword and contents (checked 22/11/2026)
Quality Magazine: Third revision of ISO 2859-1 (checked 22/11/2026)
Chinese Standard: GB/T 2828.1-2012 preview, IDT ISO 2859-1:1999 (checked 22/11/2026)
China2West: AQL table, sample size code letters (checked 22/11/2026)
QCAdvisor: ISO 2859-1 sample size table and single sampling plan (checked 22/11/2026)
Global Sources: Anatomy of the ANSI ASQ Z1.4 AQL table (checked 22/11/2026)
V-Trust: AQL table and recommended AQL levels (checked 22/11/2026)
SQC Online: Switching rules (ISO 2859-1) (checked 22/11/2026)
EUR-Lex: Regulation (EU) 2023/988 on general product safety (checked 22/11/2026)
SABER: Saudi product conformity platform (checked 22/11/2026)